THE BASIC PRINCIPLES OF DP50RB

The Basic Principles Of Dp50rb

The Basic Principles Of Dp50rb

Blog Article

one.2.2 Warning Labels Warning Labels Meaning Please very carefully read through this manual in advance of use device. The next labels are a. Do not put the system with a sloped area. Or else the accessible in the event the program product may slide, resulting in personalized injury or even the machine functions Using the cellular malfunction.

The DP-50 Qualified is an innovative, significant-general performance Ultrasound Procedure engineered that will help you get the insights you require. The Process’s effective motor and significant-velocity processing give fantastic image high-quality and a whole details administration solution.

Cookie penting untuk memfungsikan situs dengan semestinya. Untuk meningkatkan pengalaman Anda, kami menggunakan cookie untuk mengingat detail login Anda dan menyediakan login aman, mengumpulkan statistik untuk mengoptimalkan fungsionalitas situs, dan menyediakan konten yang disesuaikan dengan minat Anda.

Permits utilization of various scanned angles to type an individual graphic, causing Increased distinction resolution and enhanced visualization

Web page 145 Clean user interface Instruments: dry tender fabric, moderate soapy h2o  Process:  Use dry tender cloth to clean the area with the program. In the event the technique is soiled, moisten the gentle cloth with gentle soapy water and wipe off any stains. Use dry smooth fabric to remove any dampness and permit all tricky surfaces to absolutely air-dry. Site 146: Clear The Peripherals

Usually do not use any cables besides the cables presented With all the product by Mindray. three. Utilize the cable delivered with This technique to attach the printer. Other cables may cause electrical shock. Page 15: Mechanical Security

Overall performance Examination five.five.one Examination System Resolution Detection depth Geometric Place Precision Blackout space take a look at Report the exam pictures 5.5.two Examination Content material The picture made use of Here's just for reference, stick to the image influence in the actual NOTE: condition. Necessities: Display screen: established the contrast and brightness on the clinical application price (or perhaps the default position) Operation surroundings: dark place, simulating the clinical application surroundings. Web page seventy six In condition that the transverse resolution screening targets are horizontally shown, document the minimal length of two targets that can be Plainly identified. Repeat the operation over for that transverse resolution tests targets at other depths. As revealed in figure down below. Axial resolution ... Webpage 77 When using the convex probe, maintain the transverse resolution testing targets to NOTE: be shown close to the midline. When utilizing a linear probe with steer functionality, will not activate the steer operate when perform the transverse resolution take a look at. Zoom inside the area in which the targets Found if necessary. The diameter in the goal position at a particular depth is equal towards the transverse resolution at the depth. Web page 78 five.

5.2.three Geometric positioning precision Longitudinal geometric positioning precision  Test Action: Do adjustments as how in testing the most depth. Report the gap by 20mm Each individual section within the longitudinal targets line utilizing the measurement caliper; Pick the worth with the greatest mistake (to 20mm), compute the accuracy using the formula beneath The measurement caliper must be positioned within the higher fringe of the concentrate on, Observe:... Page 79 Transverse geometric positioning precision  Exam Action: Include the scan floor of your phantom with h2o or couple gel, Carefully contact the probe Together with the scan floor Modify the depth, making the transverse targets to become shown within the graphic. Change the main target position to get posited beside the transverse targets (the common just isn't very clear) Modify parameters like gain, TGC, producing Just about every transverse targets being clearly shown. Page 80 5.five.two.4 Blackout Region Test Stage: Go over the scan area from the phantom with drinking water or pair gel, Carefully Make contact with the probe with the scan surface area Change the depth in a reduce worth, and set the main focus at the closest place Dp50rb to the scan surface. Minimize the worth of parameters like AP, Gain until the qualifications sound just may be noticed. Web site 81: Computer software Up grade And Maintenance

Cookies are very important to the proper functioning of a website. To help your knowledge, we use cookies to recall log-in particulars and provide secure log-in, gather stats to enhance internet site features, and provide articles personalized towards your pursuits.

Soon after changing the CPU module, essential file has to be created Once more in accordance with the new MAC address and published into HDD from the equipment. Or else, the configuration perform of your solution will be dropped. After eliminating the CPU module, Remove panhead screws with washers (12 M3X6) set on the most crucial device box, you can take off the board. Webpage 118 Figure 8-29 Disassemble the Control Panel Assembly (1) Keep the higher fringe of user interface assembly, and open up up the user interface. Determine eight-30 Disassemble the User interface Assembly (2) Right after eliminating one countersunk head self-tapping screw PT3X10 mounted within the control panel and acquire out the plug on the keyboard and the most crucial unit connecting cables, you can take away the user interface assembly.

Return into the system preset interface. The option status variations into Uninstalled. The uninstalling functionality is exceptional to internal customers.

This guide might referring to information and facts safeguarded by copyright or patents and will not convey any license beneath the patent legal rights or copyright of Mindray, or of Some others. Web site 9: Statement

A smart new shape, Improved mobility and handy operation make DP-fifty well suited for all scientific options.

Take note: Around the observe, the brightness adjustment arrives right before contrast. Immediately after readjusting the keep track of’s distinction and brightness, regulate all preset and peripheral options.

Report this page